For example , the 20-110mm pe pipe vacuum cooking tank
You need to first check whether the water is coming out of the vacuum pump and whether there is any air leakage.
Water pump and filter drains need to be closed with valves
It is necessary to ensure that water comes out of the vacuum pump system before starting vacuuming
There is a flange in the middle of the water tank that needs to be blocked, and there is a partition between the two vacuum sections of the water tank that needs to be blocked with rubber skin and flange, otherwise the vacuum cannot be sucked up.
В середине резервуара есть фланец, который должен быть заблокирован, а между двумя секциями резервуара есть разрыв, который должен быть заблокирован резиновой оболочкой и фланцем, иначе вакуум не может отсосать.
Check the working status of the vacuum pump
The first step is to close all drain valves. The second step is to fill the water tank with water. The third step is to find sealing objects at both ends of the water tank. The fourth step is to turn on the water pump and vacuum pump. Open the white transparent water supply pipe valve in front of the vacuum pump to 1/2. Then measure the vacuum degree of the water tank and see if the pressure gauge displays between 0.1 and 0.7mpa.
Первый шаг - выключить все дренажные клапаны. Во-вторых, резервуар для воды полон воды. На третьем шаге найдите запечатанную вещь на обоих концах резервуара для воды, чтобы заблокировать ее. Четвертый шаг - открыть водяной насос и вакуумный насос. Откройте белый и прозрачный клапан подачи воды перед вакуумным насосом до 1/2. Затем измерьте вакуум резервуара для воды, чтобы увидеть, находится ли манометр между 0,1 и 0,7 МПа.